4. Advanced SkLineScan Software Functions
Schäfter + Kirchhoff © 2014 • Line Scan Camera SK1024U3PD Manual (05.2014) • shared_AdvancedSyncCtrl(2)_ExampleTimingDiagram.indd (05.2014)
Example Timing Diagrams of Advanced Synchronization Control
Annotations:
SyncA = LINE SYNC A (external line synchronization input, I/O connector)
SyncB = LINE SYNC B (external line synchronization input, I/O connector)
Count = internal counter
Trigger = Generated trigger pulses from the Trigger Control stage. The signal goes to the Trigger
Divider stage inside the camera. For setting the divider use the Vyyyyy<CR> command or the
'Divider' input field in the USB Camera Control dialog, p. 15.
1) direction changed
2) glitch
Trigger on falling edge
of SyncA
SyncB = low active
direction detection = on
hysteresis = 0
Sync Control Register:
'10000xxx'b
B
1)
Trigger on falling edge
of SyncA
SyncB without function
direction detection = off
hysteresis = 0
Sync Control Register:
'00000xxx'b
A
1)
Trigger on falling edge
of SyncA
SyncB = low/high active
direction detection = on
hysteresis = 0
Sync Control Register:
'11000xxx'b
C
1)
Trigger on 4 edges
of SyncA and SyncB
direction detection = on
hysteresis = 0
Sync Control Register:
'11100xxx'b
D
1)
Trigger on 4 edges
of SyncA and SyncB
direction detection = on
hysteresis = 4
Sync Control Register:
'11101xxx'b
E
2)
1)
1)1)